Reinforced Concrete Pipes are large and small diameter concrete pipes, used commonly in system like storm water drainage & culverts .
Lining of concrete pipes with various mediums available in market today viz., HDPE, PVC or GRP.
| RCP Gravity Pipe |
| Inside Diameter ID (mm) |
| 300 |
| 450 |
| 500 |
| 600 |
| 700 |
| 900 |
| 1000 |
| 1200 |
| 1500 |
| 1800 |
| 2000 |
| 2100 |
| 2200 |
| 2400 |
| 2500 |
| 2800 |
| 30000 |
Pipes Produced in compliance to BS 5911, BS EN 1916.
ASTM C 76M for the Reinforced Concrete Culvert, storm drain and sewer pipe.

RC Pipe Assembly Testing


Our pipes comply to specifications prevalent in GCC with all the client bodies
Reinforced Concrete Pipes
| Inner Diameter in millimeters | Outer Diamater in millimeters | Wall Thickness in millimeters | Approximate Weight in Kilograms |
| 300 | 440 | 70 | 537 |
| 450 | 610 | 80 | 875 |
| 500 | 670 | 85 | 1038 |
| 600 | 790 | 95 | 1085 |
| 700 | 910 | 105 | 1772 |
| 800 | 1020 | 110 | 2014 |
| 900 | 1140 | 120 | 2488 |
| 1000 | 1260 | 130 | 2881 |
| 1200 | 1470 | 135 | 3541 |
| 1500 | 1800 | 150 | 4913 |
| 1800 | 2160 | 180 | 7069 |
* Weights are representative for 2.5 meters RC pipe
Above data is subject to change, Pipe data for diameters above 1800mm up wards to 3000mm will be provided on project request.

AOCP offers Engineered solutions as per the project requirement, different pipe sizes with different technical specifications are made available on request.
Characteristic compressive strength ƒck =50 N/mm2.
* Loads Designed as per BS 5911 Factor of Safety =2.5 is representative.
The pipes are designed to withstand maximum axial thrust with a factor of safety 2.5 and based on the full effective area of the joint surface and ultimate compressive strength of the pipe material.
| Pipe Internal diameter | Allowable Jacking load* |
| (mm) | (tones) |
| 450 | 184 |
| 500 | 253 |
| 600 | 344 |
| 700 | 450 |
| 900 | 653 |
| 1000 | 794 |
| 1200 | 950 |
| 1500 | 1332 |
| 1800 | 1944 |
| 2000 | 2436 |
AOCP offers Engineered solutions as per the project requirement, different pipe sizes with different jacking forces on request. Safety Factors above 2.5 can also be provided and pipes can be designed accordingly.


AOCP Manhole System includes a comprehensive range of diameters. Mono bases with benching, riser of different heights, reducer slabs, concrete top slab cover options, with accessories like step ladder, Stanchions, joint sealants & clamps. The joint interlocking profiles of the manhole make the installation quick and effective, and the use of effective sealing material between the sections makes the system watertight.
Features
Benefits
Applications


MH Monolithic Base*
| Inside Diameter ID (mm) | Outside Diameter OD (mm) | Wall Thickness (mm) |
| 1200 | 1470 | 135 |
| 1500 | 1800 | 150 |
| 1800 | 2160 | 180 |
* Representative sizes, other sizes can be offered as per project requirements. Compliant with BS 5911-3, BS EN 1917: 2002 and ASTM C 478.
Manholes ranging from Small, medium & large sizes i.e. 1200, 1500 & 1800mm diameters. We cast manholes of different sizes as per the project requirement.
The raiser system is basically a shaft made with height adjustable sections depending on the requirement of depth to invert level, generally decided by the surveyor or the Engineer at site. AOCP ships the riser components, sealing material and monobases as per the individual site requirements. Thus making it JUST In TIME for the project management teams.
BS 5911-3
BS EN 1917: 2002
ASTM C 478. Precast manholes are preferred for greater depths due to their inherent strength, structural integrity and solution for buoyancy issues in water table areas
We cast different diameter of Manhole Risers as per the project requirement and specification of respective regions.





Keeping in mind the region’s infrastructure projects, Engineers at AOCP have come up with below standard product program. Our engineering team can work with you to design the exact precast concrete culvert you need to achieve project objectives. In our state-of-the-art manufacturing facility, we manufacture all products indoors under controlled conditions. You get higher quality, long asset life, the right solutions for your design and reduced risk of mobilization and overheads on the execution site.
Conveyance of storm water from urban developments. Designed for gravity flow of fluids. Can be used as small bridges and culverts for stream crossings where natural stream bed does not have to be maintained
The advantage precast concrete culverts offers over the cast in site structure is due to quick delivery, consistency in quality and dimensions, reliability of the product.

Custom Sizes are made to order
We currently Comply to
Above Standard Sizes or as required by the project are casted

Manufacturing
Quality Inspection
Storage, Delivery & Installation
AOCP embarks to bring economy in water and fluid transmission & distribution business replacing the age old and expensive Ductile Iron pipes with PCCP first time in the region. The pipe and its fittings manufactured right here in Oman.


Prestressed Concrete Embedded Cylinder Pipe Prestressed Concrete Lined Cylinder Pipe
Prestressed Concrete Lined Cylinder Pipe
| Pipe Diameter (mm) | Core Thickness (mm) | Joint Depth (mm) | Joint Diameter (mm) | Bell Outside Diameter (mm) | Barrel Outside Diameter (mm) | Core Length(mm) |
| 600 | 50 | 115 | 712.7 | 811 | 750 | 6000 |
| 800 | 50 | 115 | 912.7 | 1011 | 950 | 6000 |
| 1000 | 65 | 115 | 1142.7 | 1241 | 1180 | 6000 |
| 1200 | 675 | 115 | 1350 | 1453 | 1400 | 6000 |
| 1400 | 88 | 125 | 1598.2 | 1679 | 1626 | 6000 |